
The
LABTOPTM � Micro controller based platelet incubators are designed to store Platelet concentrates in continues motion at controlled temperature. The platelet Incubators are constructed of double walls. The exterior is made of mild steel (1mm thick) powder coated and the inner chamber is fabricated of stainless steel (0.8mm thick, 304).
We offer you the widest collection of platelet incubators available. from compact unit for small institutions to large floor models that offer maximum capacity and reliability.
Labtop
TM Platelet Incubators provide accurate and stable storage conditions at 22�C. This compact model takes very littlespace and will accurately incubate platelet bags when used with the Labtop
TM agitator. Labtop
TM have incorporated motion failure alarm (Optional) and recording functions that are found in the Labtop
TM Blood Bank range providing the same levels of product security. An independent 7 day circular chart recorder provides operating temperature evidence.
Special Features - Micro-controller Controls the internal temperature within � 0.5 �C .
- Unique air flow system ensures even temperature distribution.
- Formed in place CFC free PUF insulation ensures temperature stability and reduced energy consumption.
- Audio visual alarm for temperature deviation from the set temperature.
- Motion failure alarm when the agitator fails to operate.
- Automatic agitator stops when door is open.
- The LabtopTM Platelet Agitator features the unique design LabtopTM rack with high ventilation capability to allow oxygen transfer to the platelets. Smooth sliding stainless steel trays which can be removed for cleaning as well as enable easy removal or loading of bags in the tray. Fixed speed agitator with heavy duty bearings and quiet operation. When used with a labtopTM Platelet Incubator the agitator will automatically stop when the door is open.
Calibration The equipment is calibrated with the help of master calibrator, which is certified for its accuracy by Electronics Regional Testing Laboratory (ERTL West) Government of India recognized testing laboratory with traceable reference to National Physical Laboratories (NPL).
TECHNICAL SPECIFICATION | Catalogue No. | LPI - 500 | LPI - 250 | LPI - 500 |
| Volume | 125 liters | 250 liters | 500 liters |
| Temperature | 22.0�C | 22.0�C | 22.0�C |
| Accuracy | �0.5 �C | ?0.5 �C | ?0.5 �C |
| Input Voltage | 230 V AC | 230 V AC | 230 V AC |
| No. of Agitator (Optional) | Four | Two | Four |
| Temperature Control | Micro Controller | Micro Controller | Micro Controller |
| Temperature Recorder | 7 Days circular chart | 7 Days circular chart | 7 Days circular chart |
Technical Specification of Agitator | Catalogue No. | LPA-24 | LPA-36 | LPA-46 |
| No. of Platelet Bags | 24 | 36 | 48 |
| No. of tray | 4 | 6 | 8 |
| Alarm (Optional) | Audio Visual | Audio Visual | Audio Visual |
