LABTOPTM Medical refrigerators are available in a variety of configurations providing alternatives between cabinet capacity and control capability.
General Features Applications include refrigerated storage of Vaccines, Reagents, Cultures, Medicines and Blood samples. Temperature range adjustable from 2.0� C to 8.0� C with micro controller based temperature controller includes digital temperature display of set value and process value, Forced air circulation for maximum temperature uniformity. Temperature alarm system with adjustable high /low alarm limits, includes audible and visual warning.
Cabinet Construction and Refrigeration System The cabinet of Medical laboratory refrigerators are insulated with high density CFC free Poly Urethane Foam. Interior of chamber is mirror finish resistant stainless Steel (304, 0.8 mm thick). The exterior is white power coated (1.0 mm thick) MS and the door has a magnetic door gasket with a keyed door lock. Stainless steel tray or pull-trays are provided for storage inside. The cooling is effected by a hermitically sealed compressor of high quality. Complete Unit in total stainless steel (Inside S S 316, 0.8 mm thick and outside S S 304,1mm tick) is also manufactured by Skylab.
Special Features - Micro-controller controls the internal temperature within 0.5 C
- Unique air flow system ensures even temperature distribution.
- Foamed in place CFC free PUF insulation ensures consumption.
- Audio visual alarm when the temperature deviates from the pre set temperature.
- Specially designed Stainless steel trays ensure even temperature distribution.
- Directional air flow assures quick recovery after door openings
TECHNICAL SPECIFICATION | Model | LLR-170 | LLR-290 | LLR-350 | LLR-450 | LLR-600 | LLR-800 | LLR-1000 |
| Temperature Range | 2C - 8C | 2C - 8C | 2C - 8C | 2C - 8C | 2C - 8C | 2C - 8C | 2C - 8C |
| Accuracy | � 0.5 C | � 0.5 C | � 0.5 C | � 0.5 C | � 0.5 C | � 0.5 C | � 0.5 C |
| Size (WxDxH) cms | 50X41X84 | 62X52X102 | 64X66X143 | 128X66X143 | 62X52X102 | 64X66X143 | 128X66X143 |
| Volume | 170 Liters. | 290Liters. | 350 Liters. | 450 Liters. | 600Liters. | 800 Liters. | 1000 Liters. |
| No. of Baskets | Two | Five | Seven | Fourteen | Five | Seven | Fourteen |
| Operating Voltage | 230 V AC | 230 V AC | 230 V AC | 230 V AC | 230 V AC | 230 V AC | 230 V AC |
Optional Accessories Stand by Refrigeration system Ready to use stand by refrigeration system in case of regular system fails.
This includes Compressor, Evaporator, condensers and other accessories.
Safety Controller Dedicated safety controller with separate sensor to switch off the power supply in case of overshoot and undershoot of temperature giving audio visual alarm.
Data Scanner 8 channel temperature data scanner complete with sensors and printer interface and data storage facility.
Software CFR 21 Part 11 compliance web based communication software for data management. Complete with RS 485 multi dropping to monitor multiple chambers to one software.
Printer Interface Facility to store, print records on printer with set values, Process values, date and time with variable print time interval. Data storage facility to print the data online and off line, suitable for 80 col. Dot matrix printer.
P C Inter face and data management PC Interface with communication allows remote monitoring and data logging to control the chamber. Web based software having reports in tabular as well as graphical form.
PLC system For auto changeover of stand by systems and other event managements with 3.8" LCD display with touch screen
DOCUMENTATION For GMP complaint models LABTOP offers DQ IQ, OQ and PQ validation with documentation, reports, calibration and test certificates.
CALIBRATION The equipment is calibrated with the help of master calibrator, which is certified for its accuracy by Electronics Regional Testing Laboratory (ERTL West) Government of India recognized testing laboratory with traceable reference to National Physical Laboratories (NPL).